چکیده انگلیسی


• An alternative methodology for trace level analysis of parabens-type compounds.
• The comparison of the selectivity of different sorbent phases.
• Development and validation of a novel methodology using low amount of solvent.
• The application of a novel analytical approach in real matrices.
• Evaluation of the performance of BAμE device when downsizing it to half-length.

In the present work, the development of an analytical methodology which combines bar adsorptive microextraction with microliquid desorption followed by high performance liquid chromatography-diode array detection (BAμE-μLD/HPLC-DAD) is proposed for the determination of trace levels of four parabens (methyl, ethyl, propyl and buthyl paraben) in real matrices. By comparing six polymer (P1, P2, P3, P4, P5 and P6) and five activated carbon (AC1, AC2, AC3, AC4 and AC5) coatings through BAμE, AC2 exhibited much higher selectivity and efficiency from all the sorbent phases tested, even when compared with the commercial stir bar sorptive extraction with polydimethylsiloxane. Assays performed through BAμE(AC2, 1.7 mg) on 25 mL of ultrapure water samples spiked at the 8.0 μg/L level, yielded recoveries ranging from 85.6 ± 6.3% to 100.6 ± 11.8%, under optimized experimental conditions. The analytical performance showed also convenient limits of detection (0.1 μg/L) and quantification (0.3 μg/L), as well as good linear dynamic ranges (0.5–28.0 μg/L) with remarkable determination coefficients (r2 > 0.9982). Excellent repeatability was also achieved through intraday (RSD < 10.2%) and interday (RSD < 10.0%) assays. By downsizing the analytical device to half-length (BAμE(AC2, 0.9 mg)), similar analytical data was also achieved for the four parabens, under optimized experimental conditions, showing that this analytical technology can be design to operate with lower volumes of sample and desorption solvent, thus increasing the sensitivity and effectiveness. The application of the proposed analytical approach using the standard addition methodology on tap, underground, estuarine, swimming pool and waste water samples, as well as on commercial cosmetic products and urine samples, revealed good sensitivity, absence of matrix effects and the occurrence of levels of some parabens. Moreover, the present methodology is easy to implement, reliable, sensitive, requiring low sample and minimized desorption solvent volume, having the possibility to tune the most selective sorbent coating, according to the target compounds involved.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1348, 27 June 2014, Pages 17–26