کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1202514 1493553 2014 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation and validation of an accurate mass screening method for the analysis of pesticides in fruits and vegetables using liquid chromatography–quadrupole-time of flight–mass spectrometry with automated detection
ترجمه فارسی عنوان
ارزیابی و اعتبار سنجی یک روش غربالگری دقیق توالی برای تجزیه و تحلیل آفت کش ها در میوه ها و سبزیجات با استفاده از کروماتوگرافی مایع زمان جراحی طیف سنج جرمی فلما با تشخیص اتوماتیک
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A method for the screening of pesticides by UPLC–QTOF–MS has been validated.
• Optimisation is time consuming: more than 79,000 results were evaluated in this study.
• Impact of processing parameters on number of detects and false detects is evaluated.
• Challenges for the validation and implementation of a screening method are discussed.

This study reports the development and validation of a screening method for the detection of pesticides in 11 different fruit and vegetable commodities. The method was based on ultra performance liquid chromatography–quadrupole-time of flight–mass spectrometry (UPLC–QTOF–MS). The objective was to validate the method in accordance with the SANCO guidance document (12571/2013) on analytical quality control and validation procedures for pesticide residues analysis in food and feed. Samples were spiked with 199 pesticides, each at two different concentrations (0.01 and 0.05 mg kg−1) and extracted using the QuEChERS approach. Extracts were analysed by UPLC–QTOF–MS using generic acquisition parameters. Automated detection and data filtering were performed using the UNIFI™ software and the peaks detected evaluated against a proprietary scientific library containing information for 504 pesticides. The results obtained using different data processing parameters were evaluated for 4378 pesticide/commodities combinations at 0.01 and 0.05 mg kg−1. Using mass accuracy (±5 ppm) with retention time (±0.2 min) and a low response threshold (100 counts) the validated Screening Detection Limits (SDLs) were 0.01 mg kg−1 and 0.05 mg kg−1 for 57% and 79% of the compounds tested, respectively, with an average of 10 false detects per sample analysis. Excluding the most complex matrices (onion and leek) the detection rates increased to 69% and 87%, respectively. The use of additional parameters such as isotopic pattern and fragmentation information further reduced the number of false detects but compromised the detection rates, particularly at lower residue concentrations. The challenges associated with the validation and subsequent implementation of a pesticide multi-residue screening method are also discussed.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1373, 19 December 2014, Pages 40–50
نویسندگان
, , , , , ,