کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1202627 | 1493690 | 2012 | 10 صفحه PDF | دانلود رایگان |
![عکس صفحه اول مقاله: Evaluation of a generic multi-analyte method for detection of >100 representative compounds correlated to emergency events in 19 food types by ultrahigh-pressure liquid chromatography–tandem mass spectrometry Evaluation of a generic multi-analyte method for detection of >100 representative compounds correlated to emergency events in 19 food types by ultrahigh-pressure liquid chromatography–tandem mass spectrometry](/preview/png/1202627.png)
A generic extraction procedure combined with triple quadrupole mass spectrometric detection was evaluated for multi-residue analysis in 19 different foods. Measurable peaks could be obtained at relevant concentrations for 108 out of a total of 127 targeted compounds representing a wide range of physicochemical properties and compound classes related to emergency situations. Recoveries were determined for all 19 foods spiked with the 108 compounds. Seventy-five percent of the compounds had extraction recoveries of 70% or higher, with no compound below 46%. Suppression or enhancement effects on the MS response of the compounds dissolved in the extracts were low, as more than 80% of them had matrix effects between −35% and +20% and no compound was below −44% compared to matrix-free standard. In a validation, all compounds could be quantified at 200 μg/kg and 400 μg/kg food sample and 81% of the compounds at 40 μg/kg. It is concluded that the method is useful for the detection of various types of organic chemical toxicants at levels generally well below concentration thresholds for severe acute intoxication.
► We extract 108 compounds related to contingency scenarios in a single extraction step.
► We analyze all compounds in two separate UHPLC–MS/MS analytical runs (ESI+ and ESI−).
► We evaluate the method in 19 food types at relevant concentrations.
► The recoveries were high and the ion suppression effects in the ESI-interface low.
► The method meets the requirements for fast response in an emergency situation.