کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1205596 965201 2009 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Capabilities of mixed-mode liquid chromatography coupled to inductively coupled plasma mass spectrometry for the simultaneous speciation analysis of inorganic and organically-bound selenium
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Capabilities of mixed-mode liquid chromatography coupled to inductively coupled plasma mass spectrometry for the simultaneous speciation analysis of inorganic and organically-bound selenium
چکیده انگلیسی

This work investigates for the first time the potential of mixed-mode (anion-exchange with reversed-phase) high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (ICP-MS) for the simultaneous retention and selective separation of a range of inorganic and organically-bound selenium (Se) species. Baseline separation and detection of selenocystine (SeCys2), Se-methyl-selenocysteine (SeMC), selenomethionine (SeMet), methylseleninic acid (MSA), selenite, γ-glutamyl-methyl-selenocysteine (γ-glutamyl-SeMC), and selenate in a Se standard mixture by mixed-mode HPLC-ICP-MS was achieved by switching between two citrate mobile phases of different pH and ionic strength within a single chromatographic run of 20 min. Limits of detection obtained for these Se species ranged from 80 ng kg−1 (for SeMC) to 123 ng kg−1 (for selenate). Using this approach as developed for selenium speciation, an adequate separation of inorganic and organic As compounds was also achieved. These include arsenite, arsenate, arsenobetaine (AsB) and dimethylarsenic acid (DMA), which may coexist with Se species in biological samples. Application of the newly proposed methodology to the investigation of the elemental species distribution in watercress (used as the model sample) after enzymatic hydrolysis or leaching in water by accelerated solvent extraction (ASE) was addressed. Only SeMet, SeMC and selenate could be tentatively identified in watercress extracts by mixed-mode HPLC-ICP-MS and retention time matching with standards. Recoveries (n = 3) of these Se species from samples spiked with standards averaged 102% (for SeMC), 94.9% (for SeMet) and 98.3% (for selenate). Verification of the presence of SeMet and SeMC in an enzymatic watercress extract was achieved by on-line HPLC-ESI MS/MS in selected reaction monitoring (SRM) mode.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1216, Issue 42, 16 October 2009, Pages 7001–7006
نویسندگان
, , , , ,