کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1206149 | 965221 | 2009 | 7 صفحه PDF | دانلود رایگان |
This paper details an on-flow liquid chromatography–ultraviolet–nuclear magnetic resonance (LC–UV–NMR) method for the retrospective detection and identification of alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs), the markers of the toxic nerve agents for verification of the Chemical Weapons Convention (CWC). Initially, the LC–UV–NMR parameters were optimized for benzyl derivatives of the APAs and AAPAs. The optimized parameters include stationary phase C18, mobile phase methanol:water 78:22 (v/v), UV detection at 268 nm and 1H NMR acquisition conditions. The protocol described herein allowed the detection of analytes through acquisition of high quality NMR spectra from the aqueous solution of the APAs and AAPAs with high concentrations of interfering background chemicals which have been removed by preceding sample preparation. The reported standard deviation for the quantification is related to the UV detector which showed relative standard deviations (RSDs) for quantification within ±1.1%, while lower limit of detection upto 16 μg (in μg absolute) for the NMR detector. Finally the developed LC–UV–NMR method was applied to identify the APAs and AAPAs in real water samples, consequent to solid phase extraction and derivatization. The method is fast (total experiment time ∼2 h), sensitive, rugged and efficient.
Journal: Journal of Chromatography A - Volume 1216, Issue 27, 3 July 2009, Pages 5228–5234