Method validation for the analysis of 169 pesticides in soya grain, without clean up, by liquid chromatography–tandem mass spectrometry using positive and negative electrospray ionization
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Method validation for the analysis of 169 pesticides in soya grain, without clean up, by liquid chromatography–tandem mass spectrometry using positive and negative electrospray ionization
چکیده انگلیسی

Part of a comprehensive study on the comparison of different extraction methods, GC–MS(/MS) and LC–MS/MS detection methods and modes, for the analysis of soya samples is described in this paper. The validation of an acetone-based extraction method for analysis of 169 pesticides in soya, using LC–MS/MS positive and negative electrospray ionisation (ESI) mode, is reported. Samples (5 g) were soaked with 10 g water and subsequently extracted with 100 mL of a mixture of acetone, dichloromethane and light petroleum (1:1:1), in the presence of 15 g anhydrous sodium sulphate. After centrifugation, aliquots of the extract were evaporated and reconstituted in 1.0 mL of methanol, before direct injection of the final extract (corresponding with 0.05 g soya mL−1) into the LC–MS/MS system. Linearity, r2 of calibration curves, instrument limit of detection/quantitation (LOD/LOQ) and matrix effect were evaluated, based on seven concentrations measured in 6-fold. Good linearity (at least r2 ≥ 0.99) of the calibration curves was obtained over the range from 0.1 or 0.25 to 10.0 ng mL−1, corresponding with pesticide concentrations in soya bean extract of 2 or 5–200 μg kg−1. Instrument LOD values generally were 0.1 or 0.25 ng mL−1. Matrix effects were negligible for ≈90% of the pesticides. The accuracy, precision and method LOQ were determined via recovery experiments, spiking soya at 10, 50, 100 μg kg−1, six replicates per level. In both ESI modes, method LOQ values were mostly 10 or 50 μg kg−1 and more than 70% of pesticides analysed by each mode met the acceptability criteria of recovery (70–120%) and RSD (≤20%), at one or more of the three levels studied. A fast, easy and efficient method with acceptable performance was achieved for a difficult matrix as soya, without cleanup.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1142, Issue 2, 23 February 2007, Pages 123–136