کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1220432 1494641 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of flibanserin and tadalafil in supplements for women sexual desire enhancement using high-performance liquid chromatography with tandem mass spectrometer, diode array detector and charged aerosol detector
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of flibanserin and tadalafil in supplements for women sexual desire enhancement using high-performance liquid chromatography with tandem mass spectrometer, diode array detector and charged aerosol detector
چکیده انگلیسی


• The adulteration of herbal supplements for female sexual drive increase was detected.
• The identification of flibanserin, tadalafil by LC–ESI-MS/MS-TOF was discussed.
• Combined LC-DAD-CAD–MS-TOF method was developed to quantify detected adulterants.
• Determination of flibanserin and tadalafil without their standards was presented.
• The inaccuracy of proposed indirect determination was found to be ±3%.

The new compound – flibanserin – begun to appear as a synthetic adulterant in counterfeit herbal supplements used to stimulate women sexual drive. It was detected in two samples submitted to the Polish National Medicines Institute for analysis. The second sample contained also tadalafil. This study presents the LC method development which enables the determination of flibanserin and tadalafil. It employs three different detectors charged aerosol detector (CAD), diode array detector (DAD) and mass spectrometer (MS). The conditions of the elaborated method were optimized to obtain the highest sensitivity and the best resolution, especially the separation of icariin – the natural compound observed often in supplements for sexual disorders. The validation of the method proved good linearity, good accuracy and precision of the measurements recorded by all three detectors. Additionally, for CAD data, an alternative calculation method using a unified calibration function was presented and evaluated. It seems that this is the way to overcome the problem of non-availability of the reference standard of a target compound. Flibanserin content was quantified using the data of other reference standard (tadalafil). The inaccuracy of proposed indirect determination was found to be ±3%. A statistical evaluation proved that the results obtained with all detection modes and the results calculated using a unified calibration were not significantly different (p > 0.05).

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 94, June 2014, Pages 45–53
نویسندگان
, , , ,