کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1220478 1494619 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Establishment of a two-dimensional chiral HPLC system for the simultaneous detection of lactate and 3-hydroxybutyrate enantiomers in human clinical samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Establishment of a two-dimensional chiral HPLC system for the simultaneous detection of lactate and 3-hydroxybutyrate enantiomers in human clinical samples
چکیده انگلیسی


• We established a 2D high-performance liquid chromatography (HPLC) system.
• Lactate (LA)/3-hydroxybutyrate (3HB) enantiomers were detected in clinical samples.
• LA and 3HB were pre-columnderivatized with the fluorescent reagent NBD-COCl.
• LA/3HB were separated with monolithic octadecylsilane and enantioselective columns.
• The method can be used to assess LA/3HBenantiomer levels under disease conditions.

A two-dimensional chiral high-performance liquid chromatography system was established for simultaneous detection of lactate (LA) and 3-hydroxybutyrate (3HB) enantiomers in human clinical samples. d-LA is increased upon kidney damage but 3HB protected against kidney injury. Therefore, determining the concentrations of d,l-LA and d,l-3HB simultaneously would be useful for evaluating pathological conditions. LA and 3HB were pre-column-derivatized with the fluorescent reagent 4-(N-chloroformylmethyl-N-methylamino)-7-nitro-2,1,3-benzoxadiazole (NBD-COCl) at 60 °C for 15 min and separated in the first dimension with a capillary monolithic octadecylsilane column. The mobile phase consisted of 13% acetonitrile and 0.05% tirfluoroacetic acid in water. Chiralpak QD-AX and KSAACSP-001S enantioselective columns were used in the second dimension to separate LA and 3HB enantiomers, respectively. Mobile phases were mixed solutions of methanol and acetonitrile containing formic acid. The separation factors were 1.14 and 1.08, respectively. The detection limit of LA and 3HB enantiomers was 10 fmol/injection. This method was applied to human clinical samples; intra- and inter-day relative standard deviations of LA and 3HB enantiomers were, respectively, 1.04–3.25% and 1.61–5.12% in plasma, 9.19–11.2% and 4.60–5.89% in urine, and 7.12–8.90% and 2.86–6.97% in saliva. This novel analytical method is a powerful tool for investigating variations in LA and 3HB enantiomers under disease conditions.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 116, 10 December 2015, Pages 80–85
نویسندگان
, , , , , , , , ,