کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1220741 1494624 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of liquid chromatographic method for the analysis of dabigatran etexilate mesilate and its ten impurities supported by quality-by-design methodology
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Development of liquid chromatographic method for the analysis of dabigatran etexilate mesilate and its ten impurities supported by quality-by-design methodology
چکیده انگلیسی


• Gradient LC method for the analysis of dabigatran and its ten impurities is developed.
• Method development was supported by QbD concept that involved DoE–DS methodology.
• Error in model coefficients calculation was propagated to provide quality assurance.
• DS was computed as the region fulfilling the desired quality with probability π ≥ 95.

In this paper, the development of reversed-phase liquid chromatographic method for the analysis of dabigatran etexilate mesilate and its ten impurities supported by quality by design (QbD) approach is presented. The defined analytical target profile (ATP) was the efficient baseline separation and the accurate determination of the investigated analytes. The selected critical quality attributes (CQAs) were the separation criterions between the critical peak pairs because the mixture complexity imposed a gradient elution mode. The critical process parameters (CPPs) studied in this research were acetonitrile content at the beginning of gradient program, acetonitrile content at the end of gradient program and the gradient time. Plan of experiments was defined by Box–Behnken design. The experimental domains of the three selected factors x1 – content of the acetonitrile at the start of linear gradient, x2 – content of the acetonitrile at the end of linear gradient and x3 – gradient time (tG) were [10%, 30%], [48%, 60%] and [8 min, 15 min], respectively. In order to define the design space (DS) as a zone where the desired quality criteria is met providing also the quality assurance, Monte Carlo simulations were performed. The uniform error distribution equal to the calculated standard error was added to the model coefficient estimates. Monte Carlo simulation included 5000 iterations in each of 3969 defined grid points and the region having the probability π ≥ 95% to achieve satisfactory values of all defined CQAs was computed. As a working point, following chromatographic conditions suited in the middle of the DS were chosen: 22% acetonitrile at the start of gradient program, 55.5% acetonitrile at the end of gradient program end and the gradient time of 11.5 min. The developed method was validated in order to prove its reliability.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 111, 10 July 2015, Pages 7–13
نویسندگان
, , , , ,