کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1221226 1494653 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reproducibility of the anti-Factor Xa and anti-Factor IIa assays applied to enoxaparin solution
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Reproducibility of the anti-Factor Xa and anti-Factor IIa assays applied to enoxaparin solution
چکیده انگلیسی


• We evaluated the reproducibility of the potency assay of enoxaparin.
• Coefficient of variation for reproducibility of anti-Xa assay across sites was 1.2%.
• This good reproducibility is the result of assay design and standardization.
• This provides confidence for release of enoxaparin solution per USP specification.

Enoxaparin is a widely used subcutaneously administered antithrombotic agent comprising a complex mixture of glycosaminoglycan chains. Owing to this complexity, its antithrombotic potency cannot be defined by physicochemical methods and is therefore evaluated using an enzymatic assay of anti-Xa and anti-IIa activity. Maintaining consistent anti-Xa activity in the final medicinal product allows physicians to ensure administration of the appropriate dosage to their patients. Bioassays are usually complex and display poorer reproducibility than physicochemical tests such as HPLC assays. Here, we describe the implementation of a common robotic platform and standard release potency testing procedures for enoxaparin sodium injection (Lovenox®, Sanofi, Paris, France) products at seven quality control sites within Sanofi. Qualification and analytical procedures, as well as data handling, were optimized and harmonized to improve assay reproducibility. An inter-laboratory study was performed in routine-release conditions. The coefficients of variation for repeatability and reproducibility in assessments of anti-Xa activity were 1.0% and 1.2%, respectively. The tolerance interval in reproducibility precision conditions, expressed as percentage potency, was 96.8–103.2% of the drug product target of 10,000 IU/ml, comparing favorably with the United States of America Pharmacopeia specification (90–110%). The maximum difference between assays in two different laboratories is expected to be 4.1%. The reproducibility characteristics of anti-IIa activity assessments were found to be similar. These results demonstrate the effectiveness of the standardization process established and allow for further improvements to quality control in Lovenox® manufacture. This process guarantees closeness between actual and target potencies, as exemplified by the results of release assays obtained during a three-year period.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volumes 81–82, July–August 2013, Pages 138–145
نویسندگان
, , , ,