کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1223555 967894 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous enantioseparation of a basic active pharmaceutical ingredient compound and its neutral intermediate using reversed phase and normal phase liquid chromatography with a new type of polysaccharide stationary phase
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous enantioseparation of a basic active pharmaceutical ingredient compound and its neutral intermediate using reversed phase and normal phase liquid chromatography with a new type of polysaccharide stationary phase
چکیده انگلیسی

Simultaneous enantioseparation of a basic API compound, (R)-2-Amino-N-[2-[1,2-dihydro-1-(methylsulfonyl) spiro [3H-indole-3,4′-piperidin]-1′-yl]-2-oxo-1-[(phenylmethyloxy) ethyl]-2-methylpropanamide monomethanesulfonate (compound-A) and its neutral penultimate intermediate, (R)-2-BOC-Amino-N-[2-[1,2-dihydro-1-(methylsulfonyl) spiro [3H-indole-3,4′-piperidin]-1′-yl]-2-oxo-1-[(phenylmethyloxy) ethyl]-2-methylpropanamide monomethanesulfonate (compound-B) was investigated using reversed phase (RPLC) and normal phase liquid chromatography (NPLC). After an initial screening, a Sepapak-4 column, a new type of polysaccharide chiral stationary phase (CSP), was selected for further method development based on hits on separation selectivity for both compounds under RPLC and NPLC. After comparing the pros and cons, a method utilizing the Sepapak-4 chiral column (150 mm × 4.6 mm, 3 μm particle size) in RPLC mode was finally developed. Separations were performed in gradient elution mode starting at 50% A (10 mM, NH4COOH at pH 6.5)/50% B (50/50 EtOH/MeCN) to 25% A (10 mM, NH4COOH at pH 6.5)/75% B (50/50 EtOH/MeCN). The flow rate was 1.0 mL/min; the column temperature was 50 °C; the UV wavelength was 220 nm and the mass spectrometric detection was APCI in the positive ionization mode. The reaction mixture sample was directly diluted in ethanol. Baseline enantioseparation were achieved for both compound-A and its intermediate simultaneously with resolution greater than 2.0. The method was validated in terms of injection precision, linearity, limit of detection (LOD), limit of quantitation (LOQ), accuracy, and ruggedness. The specificity of the method was further evaluated by spiking a mixture of enantiomers of compound-A and its intermediate into a reaction matrix containing all of the synthetic reagents. No matrix interference was observed across the elution windows of compound-A and its intermediate. Additionally, the peak purity of each enantiomer was evaluated by mass spectra, indicating the specificity of the method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 51, Issue 1, 5 January 2010, Pages 153–157
نویسندگان
, , , , ,