کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1224909 967938 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Method development and validation for isoflavones in soy germ pharmaceutical capsules using micellar electrokinetic chromatography
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Method development and validation for isoflavones in soy germ pharmaceutical capsules using micellar electrokinetic chromatography
چکیده انگلیسی

The separation of six soy isoflavones (Glycitein, Daidzein, Genistein, Daidzin, Glycitin and Genistin) was approached by a 32 factorial design studying MEKC electrolyte components at the following levels: methanol (MeOH; 0–10%) and sodium dodecylsulfate (SDS; 20–70 mmol L−1); sodium tetraborate buffer (STB) concentration was kept constant at 10 mmol L−1. Nine experiments were performed and the apparent mobility of each isoflavone was computed as a function of the electrolyte composition. A novel response function (RF) was formulated based on the productory of the mobility differences, mobility of the first and last eluting peaks and the electrolyte conductance. The inspection of the response surface indicated an optimum electrolyte composition as 10 mmol L−1 STB (pH 9.3) containing 40 mmol L−1 SDS and 1% MeOH promoting baseline separation of all isoflavones in less than 7.5 min.The proposed method was applied to the determination of total isoflavones in soy germ capsules from four different pharmaceutical laboratories. A 2 h extraction procedure with 80% (v/v) MeOH under vortexing at room temperature was employed. Peak assignment of unknown isoflavones in certain samples was assisted by hydrolysis procedures, migration behavior and UV spectra comparison. Three malonyl isoflavone derivatives were tentatively assigned. A few figures of merit for the proposed method include: repeatability (n = 6) better than 0.30% CV (migration time) and 1.7% CV (peak area); intermediate precision (n = 18) better than 6.2% CV (concentration); recoveries at two concentration levels, 20 and 50 μg mL−1, varied from 99.1 to 103.6%. Furthermore, the proposed method exhibited linearity in the concentration range of 1.6–50 μg mL−1 (r2 > 0.9999) with LOQ varying from 0.67 to 1.2 μg mL−1. The capsules purity varied from 93.3 to 97.6%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 41, Issue 5, 28 August 2006, Pages 1625–1632
نویسندگان
, , , , ,