چکیده انگلیسی


• Surface modification of MIL-101 with Triton X-114 was investigated.
• MIL-101 after modification was applied to dispersive solid-phase extraction.
• Enhanced performance in extraction of estrogens was obtained.
• Post-extraction derivatization coupled with GC–MS analysis was used.

The research presented in this paper explored the modification and application of a metal-organic framework, MIL-101, with nonionic surfactant-Triton X-114 in dispersive solid-phase extraction for the preconcentration of four endocrine disrupting chemicals (estrone, 17α-ethynylestradiol, estriol and diethylstilbestrol) from environmental water samples. Triton X-114 molecules could be adsorbed by the hydrophobic surface of the MIL-101 crystals, and thus improved the dispersibility of MIL-101 in aqueous solution by serving as a hydrophilic coating. Cloud point phase separation from Triton X-114 accelerated the separation of extracts from the aqueous matrix. The proposed method combines the favorable attributes of strong adsorption capacity resulting from the porous structure of MIL-101 and self-assembly of Triton X-114 molecules. Post-extraction derivatization using N-methyl-N-(trimethylsilyl)trifluoroacetamide was employed to facilitate the quantitative determination of the extracts by gas chromatography–mass spectrometry. The main factors affecting the preparation of modified MIL-101, and extraction of the analytes, such as the amount of surfactant, the ultrasonic and vortex durations, solution pH and desorption conditions, were investigated in detail. Under the optimized conditions, the present method yielded low limits of detection (0.006–0.023 ng/mL), good linearity from 0.09 to 45 ng/mL (coefficients of determination higher than 0.9980) and acceptable precision (relative standard deviations of 2.2–13%). The surface modified MIL-101 was demonstrated to be effective for the extraction of the selected estrogens from aqueous samples, giving rise to markedly improved extraction performance compared to the unmodified MIL-101.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 143, 1 October 2015, Pages 366–373
نویسندگان
, ,