کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1242062 1495803 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ultrasensitive turn-on fluorescent detection of trace thiocyanate based on fluorescence resonance energy transfer
ترجمه فارسی عنوان
تشخیص فلورسنت روشنایی حساسیت تیتانیوم ردیابی بر اساس انتقال انرژی رزونانس فلورسانس
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A fluorescent off-on probe for trace thiocyanate (SCN−) was exploited.
• The assay for SCN− is ultrasensitive with detection limit 0.09 nM.
• The method cost is 0.2$ per sample with the aid of fluorescence spectrometer.
• The operation is ultraselective and relatively fast response time within10 min.

Thiocyanate (SCN−) is a small anion byproduct of cyanide metabolism. Several methods have been reported to measure SCN− above the micromolar level. However, SCN− is derived from many sources such as cigarettes, waste water, food and even car exhaust and its effect is cumulative, which makes it necessary to develop methods for the detection of trace SCN−. In this paper, a simple and ultrasensitive turn-on fluorescence assay of trace SCN− is established based on the fluorescence resonance energy transfer (FRET) between gold nanoparticles (AuNPs) and fluorescein. The detection limit is 0.09 nM, to the best of our knowledge, which has been the lowest detection LOD ever without the aid of costly instrumentation. The fluorescence of fluorescein is significantly quenched when it is attached to the surface of AuNPs. Upon the addition of SCN−, the fluorescence is turned on due to the competition action between SCN− and fluorescein towards the surface of AuNPs. Under an optimum pH, AuNPs size and concentration, incubation time, the fluorescence enhancement efficiency [(IF−I0)/I0] displays a linear relationship with the concentration of SCN− in the range of 1.0 nM to 40.0 nM. The fluorescein–AuNP sensor shows absolutely high selectivity toward SCN− than other 16 anions. The common metal ions, amino acids and sugars have no obvious interference effects. The accuracy and precision were evaluated based on the recovery experiments. The cost effective sensing system is successfully applied for the determination of SCN− in milk products and saliva samples.

A simple and ultrasensitive turn-on fluorescence assay of trace thiocyanate (SCN−) is established based on the fluorescence resonance energy transfer (FRET) between the gold nanoparticles (AuNPs) and fluorescein. The limit of detection is 0.09 nM which has been the lowest ever reported without the expensive instrumentation to our best of knowledge.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 132, 15 January 2015, Pages 619–624
نویسندگان
, , , ,