کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1242137 1495785 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A compact high resolution electrospray ionization ion mobility spectrometer
ترجمه فارسی عنوان
اسپکترومتر جذب یون یونیزاسیون الکترو اسپری جمع و جور با وضوح بالا
کلمات کلیدی
طیف سنجی حرکت یون، الکترو اسپری، تجزیه و تحلیل آب، سه شاتر شبکه یونی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Compact electrospray ion mobility spectrometer.
• Resolving power of R=100 using an only 75 mm long drift tube.
• Novel three grid ion shutter.
• Desolvation region can be heated separately from the drift region.
• Parametric studies of temperature influence and solvent composition.

Electrospray is a commonly used ionization method for the analysis of liquids. An electrospray is a dispersed nebular of charged droplets produced under the influence of a strong electrical field. Subsequently, ions are produced in a complex process initiated by evaporation of neutral solvent molecules from these droplets. We coupled an electrospray ionization source to our previously described high resolution ion mobility spectrometer with 75 mm drift tube length and a drift voltage of 5 kV. When using a tritium source for chemical gas phase ionization, a resolving power of R=100 was reported for this setup. We replaced the tritium source and the field switching shutter by an electrospray needle, a desolvation region with variable length and a three-grid shutter for injecting ions into the drift region. Preliminary measurements with tetraalkylammonium halides show that the current configuration with the electrospray ionization source maintains the resolving power of R=100. In this work, we present the characterization of our setup. One major advantage of our setup is that the desolvation region can be heated separately from the drift region so that the temperature in the drift region stays at room temperature even up to desolvation region temperatures of 100 °C. We perform parametric studies for the investigation of the influence of temperature on solvent evaporation with different ratios of water and methanol in the solvent for different analyte substances. Furthermore, the setup is operated in negative mode and spectra of bentazon with different solvents are presented.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 150, 1 April 2016, Pages 1–6
نویسندگان
, , , , , ,