کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1243238 1495776 2016 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Electrochemically reduced graphene oxide-modified screen-printed carbon electrodes for a simple and highly sensitive electrochemical detection of synthetic colorants in beverages
ترجمه فارسی عنوان
الکترودهای کربن روی صفحه نمایش چاپ شده با الکتروشیمیایی اصلاح شده گرافن برای تشخیص الکتروشیمیایی ساده و بسیار حساس از رنگ های مصنوعی در نوشیدنی ها
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• The simultaneous determination of SY and TZ based on ERGO-modified SPCE was proposed.
• High sensitivity with excellent selectivity was obtained.
• The preparation of sensor was performed in one step.
• The sensing platform offers a rapid, simple and inexpensive determination.

A simple and highly sensitive electrochemical sensor based on an electrochemically reduced graphene oxide-modified screen-printed carbon electrode (ERGO-SPCE) for the simultaneous determination of sunset yellow (SY) and tartrazine (TZ) was proposed. An ERGO film was coated onto the electrode surface using a cyclic voltammetric method and then characterized by scanning electron microscopy (SEM). In 0.1 M phosphate buffer at a pH of 6, the two oxidation peaks of SY and TZ appeared separately at 0.41 and 0.70 V, respectively. Surprisingly, the electrochemical response remarkably increased approximately 90- and 20-fold for SY and TZ, respectively, using the modified electrode in comparison to the unmodified electrode. The calibration curves exhibited linear ranges from 0.01 to 20.0 µM for SY and from 0.02 to 20.0 µM for TZ. The limits of detection were found to be 0.50 and 4.50 nM (at S/N=3) for SY and TZ, respectively. Furthermore, this detection platform provided very high selectivity for the measurement of both colorants. This electrochemical sensor was successfully applied to determine the amount of SY and TZ in commercial beverages. Comparison of the results obtained from this proposed method to those obtained by an in-house standard technique proved that this developed method has good agreement in terms of accuracy for practical applications. This sensor offers an inexpensive, rapid and sensitive determination. The proposed system is therefore suitable for routine analysis and should be an alternative method for the analysis of food colorants.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 160, 1 November 2016, Pages 113–124
نویسندگان
, , , ,