چکیده انگلیسی


• SS-GF AAS can be used as a fast and screening technique for the determination of iAs in fish and seafood.
• Molecular absorption due to the PO was observed with high-resolution continuum source SS-GF AAS.
• The method developed in this study is a simple, fast and inexpensive option.
• The AB concentration was added to As concentration found by SS-GF AAS, agreeing with certified value.

Direct solid sample analysis with graphite furnace atomic absorption spectrometry (SS-GF AAS) was investigated initially with the intention of developing a method for the determination of total As in fish and other seafood. A mixture of 0.1% Pd+0.06% Mg+0.06% Triton X-100 was used as the chemical modifier, added in solution over the solid samples, making possible the use of pyrolysis and atomization temperatures of 1200 °C and 2400 °C, respectively. The sample mass had to be limited to 0.25 mg, as the integrated absorbance did not increase further with increasing sample mass. Nevertheless, the recovery of As from several certified reference materials was of the order of 50% lower than the certified value. Strong molecular absorption due to the phosphorus monoxide molecule (PO) was observed with high-resolution continuum source AAS (HR CS AAS), which, however, did not cause any spectral interference. A microwave-assisted digestion with HNO3/H2O2 was also investigated to solve the problem; however, the results obtained for several certified reference materials were statistically not different from those found with direct SS-GF AAS. Accurate values were obtained using inductively coupled plasma mass spectrometry (ICP-MS) to analyze the digested samples, which suggested that organic As compounds are responsible for the low recoveries. HPLC–ICP-MS was used to determine the arsenobetaine (AB) concentration. Accurate results that were not different from the certified values were obtained when the AB concentration was added to the As concentration found by SS-GF AAS for most certified reference materials (CRM) and samples, suggesting that SS-GF AAS could be used as a fast screening procedure for inorganic As determination in fish and seafood.