کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1246445 969756 2006 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Generation and characterization of polyclonal antibodies against microcystins—Application to immunoassays and immunoaffinity sample preparation prior to analysis by liquid chromatography and UV detection
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Generation and characterization of polyclonal antibodies against microcystins—Application to immunoassays and immunoaffinity sample preparation prior to analysis by liquid chromatography and UV detection
چکیده انگلیسی

Polyclonal antibodies against microcystin-LR (MC-LR), a cyclic heptapeptide toxin, were generated in rabbits using MC-LR-BSA. An enzyme-linked immunosorbent assay (ELISA) was developed for the characterization of the antibodies and their potential use for analytical purposes. The concentration of MC-LR that inhibits 50% of antibody–antigen binding (IC50) was 0.5 μg L−1 for the indirect ELISA format and 0.9 μg L−1 for the direct ELISA, using MC-LR-horseradish peroxidase conjugate. The limit of detection corresponding to IC80 was found to be 0.06 μg L−1, well below the Word Health Organization level for drinking water of 1 μg L−1. The direct competitive ELISA was applied to water samples and was shown useful for screening purposes. The developed anti-microcystin antibodies were immobilized on solid supports for use in selective solid phase extraction (SPE) systems, prior to liquid chromatography (LC) quantification. An immunoaffinity cartridge (IAC), a Sepharose®-based cartridge incorporating 2 mg of antibodies allowed the selective and quantitative recovery of a mixture of 0.2 μg of MCs showing potential use in sample preparation of real matrices. When applied to water and green algae samples, average recoveries from Sepharose®-based cartridges were in the range of 86–113% for water samples and 85–92% for blue-green algae samples. Selectivity of the IAC clean-up was proven by comparison with non-specific solid phase extraction using octadecylsilica (ODS) sorbent. Results obtained using LC/UV after IAC clean-up agreed well with results obtained using liquid chromatography and mass spectrometry detection (LC/MS and LC/MS/MS) after SPE-C18 clean-up, allowing therefore to validate the resulting technique.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 70, Issue 2, 15 September 2006, Pages 225–235
نویسندگان
, , , , ,