کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1420473 1508929 2014 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Correlation between the beam profile from a curing light and the microhardness of four resins
ترجمه فارسی عنوان
همبستگی بین پروفیل پرتو از یک نور پخت و میکرواستفاده از چهار رزین
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
چکیده انگلیسی


• The spatial irradiance and spectral emission from a LCU may not be homogeneous.
• LCUs with an inhomogeneous output can affect localized hardness values of RBCs.
• Researchers and manufacturers should be aware of the effects of beam inhomogeneity.

ObjectiveTo demonstrate the effect of localized irradiance and spectral distribution inhomogeneities of one LED-based dental light-curing unit (LCU) on the corresponding microhardness values at the top, and bottom surfaces of four dental resin-based composites (RBCs), which contained either camphorquinone (CQ) alone or a combination of CQ and monoacylphosphine oxide (TPO) as photoinitiators.MethodsLocalized irradiance beam profiles from a polywave LED-based LCU were recorded five times using a laser beam analyzer, without and with either a 400 nm or 460 nm narrow bandpass filter placed in front of the camera lens. Five specimens of each of the four RBCs (two containing CQ/TPO and two containing CQ-only) were exposed for 5-, 10-, or 30-s with the light guide directly on the top surface of the RBC. After 24 h, Knoop microhardness values were measured at 45 locations across the top and bottom surfaces of each specimen. Microhardness readings for each RBC surface and exposure time were correlated with localized patterns of the LCU beam profile, measured using the 400 nm and 460 nm bandpass filters. Spearman rank correlation was used to avoid relying on an assumption of a bivariate normal distribution for the KHN and irradiance.ResultsThe local irradiance and spectral emission values were not uniformly distributed across the light tip. There was a strong significant positive correlation with the irradiance beam profile values from the LCU taken through bandpass filters and the microhardness maps of the RBC surfaces exposed for 5 and 10 s. The strength of this correlation decreased with increasing exposure time for the RBCs containing CQ only, and increased for the RBCs containing both CQ and TPO.ConclusionsLocalized beam and spectral distributions across the tip end of the light guide strongly correlated with corresponding areas of microhardness in both the top and bottom surfaces among four RBCs with different photoinitiator contents.SignificanceA light-curing unit with a highly inhomogeneous light output can adversely affect localized microhardness of resin-based composites and this may be a contributing factor for premature failure of a restoration.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Dental Materials - Volume 30, Issue 12, December 2014, Pages 1345–1357
نویسندگان
, , , , , ,