Fracture toughness testing: A discriminatory mechanical testing performance indicator for glass-ionomer restoratives?
ترجمه فارسی عنوان
تست چقرمگی شکست: یک شاخص عملکرد تست مکانیکی تبعیض آمیز برای بازسازی های شیشه ایونومر؟
کلمات کلیدی
بازسازی شیشه ایونوم، پودر: نسبت مخلوط مایع، تست چقرمگی شکستگی، کپسوله سازی، دست مخلوط
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
چکیده انگلیسی

ObjectivesTo investigate the single-edge notched (SEN) bend fracture toughness (KIC) testing methodology as a reproducible and discriminatory mechanical testing protocol for encapsulated and hand-mixed glass-ionomers (GI).MethodsSEN bend test-pieces (35.0 ± 0.1 mm length, 6.0 ± 0.1 mm width, 3.0 ± 0.1 mm thickness with a sharp notch formed at mid-length by embedding a scalpel blade) were prepared for KIC testing using three encapsulated GI products (Chemfil Rock, Fuji IXGP Fast Capsule and Ionofil Molar AC). In addition, test-pieces were prepared from a hand-mixed GI product (Ionofil Molar) which contained between 100% and 20% of the manufacturer's recommended powder content (in 10% decrements) for a constant weight of liquid. Groups of 20 test-pieces were prepared for each encapsulated GI product (n = 3) and hand-mixed GI powder:liquid mixing ratio (n = 9). Data were statistically analyzed and the coefficients of variation (CoV) determined for each encapsulated GI product and hand-mixed GI powder:liquid mixing ratio.ResultsThe KIC testing methodology failed to discriminate between the encapsulated GI products that were investigated (p = 0.225). For the hand-mixed GI, the KIC testing methodology also failed to discriminate between the powder:liquid mixing ratios investigated (R2 = 0.576). The pooled CoV (10%) for the encapsulated GI products and for the powder:liquid mixing ratio groups (12%) identified the reproducibility of the test for this experiment. For the hand-mixed GI mixing ratio groups with between 100% to 50% of the recommended powder content, no trend could be discerned.SignificanceThe KIC testing methodology failed to discriminate between different encapsulated GI products and hand-mixed GI powder:liquid mixing ratio groups investigated, despite KIC being an intrinsic material property and the coefficient of variation being acceptable.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Dental Materials - Volume 31, Issue 8, August 2015, Pages 877–886
نویسندگان
, , ,