کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1420914 986387 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites
ترجمه فارسی عنوان
تاثیر ضخامت بر ریزسختی و استحکام باند دوتایی کامپوزیت رزین فله
کلمات کلیدی
سختی سطح، عمق درمان، پیوند دنتین، نور خنک کننده، ترمیم کننده عقب
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
چکیده انگلیسی

ObjectivesTo investigate the influence of increment thickness on Vickers microhardness (HV) and shear bond strength (SBS) to dentin of a conventional and four bulk fill resin composites.MethodsHV and SBS were determined on specimens of the conventional resin composite Filtek Supreme XTE (XTE) and the bulk fill resin composites SDR (SDR), Filtek Bulk Fill (FBF), x-tra fil (XFIL), and Tetric EvoCeram Bulk Fill (TEBF) after 24 h storage. HV was measured either as profiles at depths up to 6 mm or at the bottom of 2 mm/4 mm/6 mm thick resin composite specimens. SBS of 2 mm/4 mm/6 mm thick resin composite increments was measured to dentin surfaces of extracted human molars treated with the adhesive system OptiBond FL, and the failure mode was stereomicroscopically determined at 40× magnification. HV profiles and failure modes were descriptively analysed whereas HV at the bottom of resin composite specimens and SBS were statistically analysed with nonparametric ANOVA followed by Wilcoxon rank sum tests (α = 0.05).ResultsHV profiles (medians at 2 mm/4 mm/6 mm): XTE 105.6/88.8/38.3, SDR 34.0/35.5/36.9, FBF 36.4/38.7/37.1, XFIL 103.4/103.9/101.9, TEBF 63.5/59.7/51.9. HV at the bottom of resin composite specimens (medians at 2 mm/4 mm/6 mm): XTE (p < 0.0001) 105.5 > 85.5 > 31.1, SDR (p = 0.10) 25.8 = 21.9 = 26.0, FBF (p = 0.16) 26.6 = 25.3 = 28.9, XFIL (p = 0.18) 110.5 = 107.2 = 101.9, TEBF (p < 0.0001) 63.0 > 54.9 > 48.2. SBS (MPa, medians at 2 mm/4 mm/6 mm): XTE (p < 0.0001) 23.9 > 18.9 = 16.7, SDR (p = 0.26) 24.6 = 22.7 = 23.4, FBF (p = 0.11) 21.4 = 20.3 = 22.0, x-tra fil (p = 0.55) 27.0 = 24.0 = 23.6, TEBF (p = 0.11) 21.0 = 20.7 = 19.0. The predominant SBS failure mode was cohesive failure in dentin.SignificanceAt increasing increment thickness, HV and SBS decreased for the conventional resin composite but generally remained constant for the bulk fill resin composites.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Dental Materials - Volume 30, Issue 10, October 2014, Pages 1104–1112
نویسندگان
, , ,