کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1421124 986394 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of surface treatment on stress distribution in immediately loaded dental implants—A 3D finite element analysis
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
پیش نمایش صفحه اول مقاله
Effect of surface treatment on stress distribution in immediately loaded dental implants—A 3D finite element analysis
چکیده انگلیسی

ObjectiveTo investigate, by means of FE analysis, the effect of surface roughness treatments on the distribution of stresses at the bone–implant interface in immediately loaded mandibular implants.Materials and methodsAn accurate, high resolution, digital replica model of bone structure (cortical and trabecular components) supporting an implant was created using CT scan data and image processing software (Mimics 13.1; Materialize, Leuven, Belgium). An anatomically accurate 3D model of a mandibular-implant complex was created using a professional 3D-CAD modeller (SolidWorks, DassaultSystèmes Solid Works Corp; 2011). Finite element models were created with one of the four roughness treatments on the implant fixture surface. Of these, three were surface treated to create a uniform coating determined by the coefficient of friction (μ); these were either (1) plasma sprayed or porous-beaded (μ = 1.0), (2) sandblasted (μ = 0.68) or (3) polished (μ = 0.4). The fourth implant had a novel two-part surface roughness consisting of a coronal polished component (μ = 0.4) interfacing with the cortical bone, and a body plasma treated surface component (μ = 1) interfacing with the trabecular bone. Finite element stress analysis was carried out under vertical and lateral forces.ResultsThis investigation showed that the type of surface treatment on the implant fixture affects the stress at the bone–implant interface of an immediately loaded implant complex. Von Mises stress data showed that the two-part surface treatment created the better stress distribution at the implant–bone interface.SignificanceThe results from this FE computational analysis suggest that the proposed two-part surface treatment for IL implants creates lower stresses than single uniform treatments at the bone–implant interface, which might decrease peri-implant bone loss. Future investigations should focus on mechanical and clinical validation of these FE results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Dental Materials - Volume 30, Issue 4, April 2014, Pages e89–e97
نویسندگان
, , , , , ,