کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1421872 986427 2011 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Nanohybrid vs. fine hybrid composite in extended Class II cavities after six years
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
پیش نمایش صفحه اول مقاله
Nanohybrid vs. fine hybrid composite in extended Class II cavities after six years
چکیده انگلیسی

ObjectivesIn a controlled prospective split-mouth study, clinical behavior of two different resin composites in extended Class II cavities was observed over six years.MethodsThirty patients received 68 direct resin composite restorations (Solobond M + Grandio: n = 36; Syntac + Tetric Ceram: n = 32) by one dentist in a private practice. All restorations were replacement fillings, 35% of cavities revealed no enamel at the bottom of the proximal box, in 48% of cavities remaining proximal enamel width was <0.5 mm. Restorations were examined according to modified USPHS criteria at baseline, and after six months, one, two, four, and six years.ResultsSuccess rate was 100% after six years of clinical service, while the drop out of patients was 0%. Neither materials nor localization of the restoration (upper vs. lower jaw) had a significant influence on clinical outcome in any criterion after six years (p > 0.05; Mann–Whitney U-test). Molar restorations performed worse regarding marginal integrity (4 years), filling integrity (6, 12, 24, 48 months), and tooth integrity (4 and 6 years). Irrespective of the resin composite used, significant changes over time were found for all criteria recorded (Friedman test; p < 0.05). Marginal quality revealed a major portion of overhangs having been clearly reduced after the one year recall (baseline: 44%; 6 months: 65%; 1 year: 47%; 2 years: 6%; 4 years: 4%; and 6 years: 3%). Beyond the 1 year recall, negative step formations significantly increased due to wear (p < 0.05), having been more pronounced in molars (87% bravo after 4 years) than in premolars (51% bravo after 4 years). Tooth integrity significantly deteriorated due to enamel cracks, which increased over time (p < 0.05). Enamel chippings and cracks were significantly more frequent in molars (26% bravo after 4 years to 35% after six years) than in premolars (9% bravo after 4 years, 11% after six years). Restoration integrity over time mainly suffered surface roughness and wear (28% after one year, 75% after two years, 84% after four years, 91% after six years).SignificancesBoth materials performed satisfactorily over the 6-year observation period. Due to the extension of the restorations, wear was clearly visible after six years of clinical service with 91% bravo ratings.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Dental Materials - Volume 27, Issue 5, May 2011, Pages 455–464
نویسندگان
, , , , ,