کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1423386 986522 2007 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Stress corrosion cracking of NiTi in artificial saliva
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد بیومتریال
پیش نمایش صفحه اول مقاله
Stress corrosion cracking of NiTi in artificial saliva
چکیده انگلیسی

ObjectivesThis paper aimed to study the mechanism of the cracking of orthodontic NiTi wire.MethodsTwo orthodontic NiTi wires were subjected: (1) optical and scanning electron microscopy (SEM) to observe the fracture surface; (2) energy dispersive X-ray spectroscopy to determine the composition of the surface product; (3) anodic polarization to remove the surface product. Samples of NiTi alloy were subjected to the constant loading test to study the stress corrosion cracking (SCC) behavior of NiTi shape memory alloy in artificial saliva.ResultsThe results showed that there were three typical areas at the fracture surface of NiTi orthodontic wire. Area ‘1’ was a tool-made notch. Crack initiated from the root of this notch and propagated to form Area ‘2’, which was perpendicular to the wire axis and covered by surface film. This film consisted of Na, K, Cl, P, S and O except Ni and Ti. The cracking process of NiTi alloy under the constant loading test depended on the pH of saliva and applied stress. The crack length was about 262 μm, the longest at 300 MPa and pH 3.0.SignificanceA tool-made notch in orthodontic NiTi wires can cause SCC. At high stress and low pH, this NiTi alloy was most sensitive to cracking.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Dental Materials - Volume 23, Issue 2, February 2007, Pages 133–137
نویسندگان
, , , , ,