Considering the unignorable factors in practice, a new time independent, 2-dimensional porous media model of room-temperature Active Magnetic Regenerative Refrigeration (AMRR) has been proposed. The 2-D model improved the existing 1-dimensional model by introducing the influence of heat transfer effect though the regenerator wall and conduction for y-axis inside the regenerator. This study compared the previous 1-D model with the 2-D model and concluded that the system can lose 22% of cooling capacity caused by air convection and the conduction loss in y can reach to 10% of cooling capacity. It is concluded that the new model will be useful to predict the performance of room AMRR for more practical conditions.
► We extend 1-D porous media model to 2-D model.
► The influences of heat transfer effect though the regenerator wall is considered.
► The conduction for y-axis inside the regenerator is evaluated.
► New model will be useful to predict AMR’s performance for more practical conditions.
Journal: Cryogenics - Volume 51, Issue 6, June 2011, Pages 347–352