کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1507837 993932 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Quarter-wave pulse tube
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد مواد الکترونیکی، نوری و مغناطیسی
پیش نمایش صفحه اول مقاله
Quarter-wave pulse tube
چکیده انگلیسی

In high-power pulse-tube refrigerators, the pulse tube itself can be very long without too much dissipation of acoustic power on its walls. The pressure amplitude, the volume-flow-rate amplitude, and the time phase between them evolve significantly along a pulse tube that is about a quarter-wavelength long. Proper choice of length and area makes the oscillations at the ambient end of the long pulse tube optimal for driving a second, smaller pulse-tube refrigerator, thereby utilizing the acoustic power that would typically have been dissipated in the first pulse-tube refrigerator’s orifice. Experiments show that little heat is carried from the ambient heat exchanger to the cold heat exchanger in such a long pulse tube, even though the oscillations are turbulent and even when the tube is compactly coiled.


► In a pulse-tube refrigerator, a long pulse tube changes the pressure–velocity phase.
► Changing this phase enables efficient addition of a second stage of refrigeration.
► The long pulse tube works well despite boundary-layer turbulence.
► The long pulse tube can be coiled compactly without penalty.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Cryogenics - Volume 51, Issue 10, October 2011, Pages 575–583
نویسندگان
, , ,