کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1508262 993961 2009 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A thin gold coated hydrogen heat pipe-cryogenic target for external experiments at COSY
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد مواد الکترونیکی، نوری و مغناطیسی
پیش نمایش صفحه اول مقاله
A thin gold coated hydrogen heat pipe-cryogenic target for external experiments at COSY
چکیده انگلیسی

A gravity assisted Gold coated heat pipe (GCHP) with 5-mm diameter has been developed and tested to cool a liquid hydrogen target for external beam experiments at COSY. The need for a narrow target diameter leads us to study the effect of reducing the heat pipe diameter to 5 mm instead of 7 mm, to study the effect of coating the external surface of the heat pipe by a shiny gold layer (to decrease the radiation heat load), and to study the effect of using the heat pipe without using 20 layers of‘ super-insulation around it (aluminized Mylar foil) to keep the target diameter as small as possible. The developed gold coated heat pipe was tested with 20 layers of super-insulation (WI) and without super-insulation (WOI). The operating characteristics for both conditions were compared to show the advantages and disadvantages.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Cryogenics - Volume 49, Issue 5, May 2009, Pages 192–197
نویسندگان
, , , , ,