کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1508462 1511075 2007 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Thermal conductivity measurement below 40 K of the CFRP tubes for the Mid-Infrared Instrument mounting struts
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد مواد الکترونیکی، نوری و مغناطیسی
پیش نمایش صفحه اول مقاله
Thermal conductivity measurement below 40 K of the CFRP tubes for the Mid-Infrared Instrument mounting struts
چکیده انگلیسی

The Mid-Infrared Instrument (MIRI) is one of four instruments on the James Webb Space Telescope observatory, scheduled for launch in 2013. It must be cooled to about 7 K and is supported within the telescope’s 40 K instrument module by a hexapod of carbon fibre reinforced plastic (CFRP) tubing. This article describes the measurement of cryogenic thermal conductivity of the candidate CFRP. Measured thermal conductivities were about 0.05 W/m K at a mean temperature of 10 K increasing to about 0.20 W/m K at a mean temperature of 40 K.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Cryogenics - Volume 47, Issues 5–6, May–June 2007, Pages 348–352