Improving distillation method and device of tritiated water analysis for ultra high decontamination efficiency
ترجمه فارسی عنوان
بهبود روش تقطیر و دستگاه تجزیه و تحلیل تریتی آب برای بهره وری از تخریب فوق العاده بالا
کلمات کلیدی
آب تترا تقطیر، بازده تخریب پذیری، بتا ناخوشایند، خنک کننده هوا
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
چکیده انگلیسی


• The improvements of method and device make the decontaminatin factor (DF) of Cs-137 of distillation reach over 450,000.
• The decontamination factor ( DF) value may be increased about 20 times by increasing the height of the container from 7 cm to 20 cm.
• The device provides an easy-handling, water-saving, low cost, stable and effective way for the distillation of triated water analysis.

It is important that monitoring environmental tritiated water for understanding the contamination dispersion of the nuclear facilities. Tritium is a pure beta radionuclide which is usually measured by Liquid Scintillation Counting (LSC). The average energy of tritum beta is only 5.658 keV that makes the LSC counting of tritium easily be interfered by the beta emitted by other radionuclides. Environmental tritiated water samples usually need to be decontaminated by distillation for reducing the interference. After Fukushima Nucleaer Accident, the highest gross beta concentration of groundwater samples obtained around Fukushima Daiichi Nuclear Power Station is over 1,000,000 Bq/l. There is a need for a distillation with ultra-high decontamination efficiency for environmental tritiated water analysis. This study is intended to improve the heating temperature control for better sub-boiling distillation control and modify the height of the container of the air cooling distillation device for better fractional distillation effect. The DF of Cs-137 of the distillation may reach 450,000 which is far better than the prior study. The average loss rate of the improved method and device is about 2.6% which is better than the bias value listed in the ASTM D4107-08. It is proven that the modified air cooling distillation device can provide an easy-handling, water-saving, low cost and effective way of purifying water samples for higher beta radionuclides contaminated water samples which need ultra-high decontamination treatment.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Environmental Radioactivity - Volume 150, December 2015, Pages 62–67