Radioxenon monitoring has become one of the major concerns in both international monitoring systems and on-site inspection. The most important technical specifications for radioxenon system are the radon removal coefficient and the minimum detectable activity concentration. We have developed one kind of on-site radioxenon sampling, separation and measurement system, and have tested it under high radon activity concentration levels. The result shows the natural 133Xe background activity concentration, the 133Xe/222Rn ratio and the radon removal coefficient to be in the ranges 0.73–1.6 mBq/m3, (1.5–3.5) × 10−8 and (2.3–57) × 10−8, respectively.
► 238U can decay to 222Rn and spontaneously fission to 133Xe simultaneously.
► Developed onsite inspection radioxenon sampling, separation and measurement system.
► System measured trace level of 133Xe concentration, under high radon concentration.
► The radon removal coefficient for the system was achieved.
► The 133Xe/222Rn ratio was calculated.
Journal: Journal of Environmental Radioactivity - Volume 122, August 2013, Pages 9–15