کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1738437 1016792 2011 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of an energy discriminate CR-39® nuclear track etch dosimeter for Radon-220 gas measurements
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
Development of an energy discriminate CR-39® nuclear track etch dosimeter for Radon-220 gas measurements
چکیده انگلیسی

An energy discriminate CR-39® nuclear track etch dosimeter for use in a 220Rn and 222Rn gas monitor has been developed and experimentally assessed. It utilises a thin film of Mylar® C to attenuate the alpha particle energies to allow only the damage tracks created by the 8.785 MeV alpha particles emitted from 212Po of the 232Th decay chain to be registered in the CR-39® plaque, allowing for the direct measurement of 220Rn gas concentrations. The dosimeter was developed through a combination of experimental investigations and theoretical simulations using the Monte Carlo ion transport modelling program Stopping and Range of Ions in Materials (SRIM 2008). A film thickness of 54 μm has been shown to attenuate all alpha energies less then 7.7 MeV.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Environmental Radioactivity - Volume 102, Issue 10, October 2011, Pages 901–905
نویسندگان
, , ,