کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1738864 1016819 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A Monte Carlo study of radon detection in cylindrical diffusion chambers
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
A Monte Carlo study of radon detection in cylindrical diffusion chambers
چکیده انگلیسی

The functioning of radon diffusion chambers was studied using the Monte Carlo code RAMMX developed here. The alpha particles from radon are assumed randomly produced in the volume of the cylinder, and those from the progeny are assumed to originate randomly at the cylindrical surface. The energy spectrum, the distribution of incident angles, and the distribution of path lengths of the alpha particles on the detector were obtained. These quantities vary depending on input parameters such as initial alpha particle energy, radius and depth of the diffusion chamber, detector size and atmospheric pressure. The calculated energy spectrum for both 222Rn and 220Rn was compared with experiment, permitting the identification of each peak and its origin, and a better understanding of radon monitoring. Three aspects not considered in previous calculations are progeny alphas coming from surfaces of the monitor, taking into account the atmospheric pressure, and including the isotope 220Rn.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Environmental Radioactivity - Volume 101, Issue 5, May 2010, Pages 333–337