کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
192006 | 459733 | 2010 | 8 صفحه PDF | دانلود رایگان |

A screen-printed carbon electrode modified with functionalized mesoporous silica nanoparticles (MTTZ-MSU-2) was developed and evaluated for reliable quantification of trace Pb(II) ions by anodic stripping square wave voltammetry in non-pretreated natural waters. The optimal operating conditions were 5 min preconcentration time and 120 s electrolysis time in HCl 0.2 M. The electrode displayed excellent linear behavior in the concentration range examined (1–30 μg L−1) with a limit of detection of 0.1 μg L−1. The screen-printed carbon modified electrode has long service time and good single and inter-electrode reproducibility. Applicability to spiked drinking water, river water and groundwater was demonstrated without any sample pre-treatment (recoveries between 97% and 106%, RSD 4–7%). On the basis of the present data, mercury-free screen-printed electrodes modified with functionalized mesoporous silicas have the potential to become the next-generation analyzers for decentralized heavy metal monitoring in environmental samples.
Journal: Electrochimica Acta - Volume 55, Issue 23, 30 September 2010, Pages 6983–6990