کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1965179 1538645 2016 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
High-throughput measurement of 25-hydroxyvitamin D by LC–MS/MS with separation of the C3-epimer interference for pediatric populations
ترجمه فارسی عنوان
اندازه گیری توان بالا 25 هیدروکسی ویتامین D با استفاده از LC-MS / MS با جداسازی تداخل C3-epimer برای جمعیت اطفال
کلمات کلیدی
ویتامین دی؛ کروماتوگرافی مایع طیف سنجی جرمی؛ C3 epimer
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی زیست شیمی
چکیده انگلیسی


• 3-epi-25-hydroxyvitamin D3 is known to interfere with 25-hydroxyvitamin D3 by LC–MS.
• The assay separates 3-epi-25-hydroxyvitamin D3 with total run time of just 4.8 min.
• The assay is fully validated for clinical use in high volume laboratories.
• The assay is standardized to NIST SRM972a.

BackgroundLiquid chromatography–tandem mass spectrometry (LC–MS/MS) is widely used for the measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in blood. However, the presence of 25OHD3 C3-epimer (3-epi-25OHD3) may cause interference and overestimation of the 25OHD3 level. We developed a rapid and simple assay for measurement of 25OHD that separates this interference and to investigate its impact on 25OHD3 measurement in adult and pediatric populations.MethodsSample preparation consisted of protein precipitation followed by solid-phase extraction with an LC run time of 4.8 min. Method comparison with another LC–MS/MS method of a major reference laboratory that does not separate the C3-epimer interference was performed using adult (n = 52) and pediatric (n = 40) samples.ResultsThis method is free from significant ion suppression, carryover and interference. The assay can separate 25OHD3 from the 3-epi-25OHD3, and can measure 25OHD2 and 25OHD3 from 4.2 to 310.7 ng/ml and 5.2 to 311.1 ng/ml, respectively. Method comparison with a LC–MS method that does not separate the interference revealed biases of − 0.15 and 4.54 for 25OHD3 measurement in adult and pediatric samples, respectively.ConclusionA fast and simple LC–MS/MS method for quantification of 25OHD3 and 25OHD2 without 3-epi-25OHD3 interference was developed. This assay is required for accurate quantitation of 25OHD3 in pediatric samples and suitable for routine use in a high volume clinical laboratory.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinica Chimica Acta - Volume 454, 15 February 2016, Pages 102–106
نویسندگان
, , , ,