کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
2502902 | 1557403 | 2012 | 9 صفحه PDF | دانلود رایگان |

In an earlier study, a micro-dosing system for fine powder using a vibrating capillary which can precisely dose various lactose powders, was introduced. In scaling up to a multi-track dosing system, it was suggested that additional track cut-offs can improve the dosing performance by reducing the overruns. A non-contact in-line control unit within a closed-loop system is required to achieve this goal. Due to its very fast response time (a few milliseconds) a capacitive sensor was integrated together with multi track cut-offs into a closed-loop dosing system. With this improvement a standard dosing deviation as low as 0.1 mg was achieved. The results suggest its application in precise filling of fine pharmaceutical powders.
Figure optionsDownload high-quality image (162 K)Download as PowerPoint slide
Journal: International Journal of Pharmaceutics - Volume 433, Issues 1–2, 20 August 2012, Pages 42–50