کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
268437 504435 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Fire design of timber slabs made of hollow core elements
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات مهندسی ژئوتکنیک و زمین شناسی مهندسی
پیش نمایش صفحه اول مقاله
Fire design of timber slabs made of hollow core elements
چکیده انگلیسی

The fire design of timber structures usually take into account both the loss in cross-section due to charring of wood and the temperature-dependent reduction of strength and stiffness of the uncharred residual cross-section. The fire behaviour of timber assemblies made of hollow core elements is characterised by different charring phases. After the fire exposed timber layer is completely charred and the char-layer has fallen off, the thin vertical timber members are exposed to fire on 3 sides, leading to very irregular residual cross-sections with charring depths much greater than for heavy timber structures. Based on an extensive experimental and parametric study, a simplified calculation model for the fire resistance of timber slabs made of hollow core elements has been developed. The calculation model bases on the reduced cross-section method and takes into account two different charring phases. The paper first describes and discusses the simplified calculation model, and then compares the test results to the calculation model.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Structures - Volume 31, Issue 1, January 2009, Pages 150–157
نویسندگان
, , ,