کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2937844 1176903 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Resting Aortic Valve Area at Normal Transaortic Flow Rate Reflects True Valve Area in Suspected Low-Gradient Severe Aortic Stenosis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Resting Aortic Valve Area at Normal Transaortic Flow Rate Reflects True Valve Area in Suspected Low-Gradient Severe Aortic Stenosis
چکیده انگلیسی

ObjectivesThis study sought to assess the diagnostic impact of stress echocardiography (SE) in patients with suspected low-flow, low-gradient aortic stenosis but normal resting transvalvular flow rate.BackgroundSE may help to distinguish between true severe aortic stenosis and pseudosevere aortic stenosis in patients with low aortic valve area (AVA) and mean gradient. However, if rest flow rate is normal, then SE may not confer any additional diagnostic value, irrespective of resting left ventricular ejection fraction (LVEF) and indexed stroke volume (SVi).MethodsSixty-seven patients with suspected low-flow, low-gradient aortic stenosis who underwent SE were retrospectively studied. Following stratification by rest LVEF, SVi, and flow rate—using cutoffs of 50%, 35 ml/m2, and 200 ml/s, respectively—we tested for significant changes in AVA during SE.ResultsMean age was 77 ± 9 years and 60% of patients were male. Mean values for rest variables were as follows: AVA: 0.77 ± 0.12 cm2; mean gradient: 27 ± 7 mm Hg; flow rate: 182 ± 37 ml/s; SVi: 32 ± 8 ml/m2; and LVEF: 45 ± 15%. During SE, significant increases in AVA were observed regardless of resting LVEF and SVi state. In patients with rest flow rate ≥200 ml/s, AVA did not increase significantly during stress (rest AVA: 0.90 cm2 vs. stress AVA: 0.97 cm2; p = 0.11), and positive predictive value for confirming underlying true severe aortic stenosis was 84%. In adjusted analyses, rest flow rate was the only parameter associated with severe AS (odds ratio: 1.05, 95% confidence interval: 1.0 to 1.1; p = 0.002).ConclusionsRest AVA measured under normal flow rate conditions is likely to reflect the true severity of AS and unlikely to change significantly with SE. Flow normalization may only be required in patients with AVA <1 cm2 and mean gradient <40 mm Hg when the rest flow rate is <200 ml/s.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Imaging - Volume 8, Issue 10, October 2015, Pages 1133–1139
نویسندگان
, , , , , ,