MR Cine DENSE Dyssynchrony Parameters for the Evaluation of Heart Failure : Comparison With Myocardial Tissue Tagging
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
MR Cine DENSE Dyssynchrony Parameters for the Evaluation of Heart Failure : Comparison With Myocardial Tissue Tagging
چکیده انگلیسی

ObjectivesWe sought to assess the effectiveness of automated mechanical dyssynchrony (MD) parameters based on regional heterogeneity of strain (circumferential [CURE], longitudinal [LURE], and radial uniformity ratio estimates) relative to parameters based on regional time to peak contraction with cardiac magnetic resonance (CMR) cine DENSE (Displacement Encoding with Stimulated Echoes) validated with myocardial tissue tagging (MTT) strain data.BackgroundDyssynchrony measures based on the Fourier transformation (FT) of regional strain, such as CURE (previously evaluated in cardiac resynchronization therapy candidates), directly assess MD and yield straightforward global dyssynchrony indexes; however, performance relative to the 12-segment standard deviation of time to peak strain (SD12) or maximal regional delay in time to peak strain is unknown.MethodsCine DENSE and MTT were obtained with CMR (1.5-T Siemens Avanto, Siemens, Erlangen, Germany) in 13 canines: 3 normal control subjects, 5 with tachycardia pacing-induced heart failure (HF) and left bundle branch ablation (LBBB-HF), and 5 with HF and narrow QRS (NQRS-HF). Strain and dyssynchrony parameters were determined with both CMR methods.ResultsBoth HF groups had reduced peak strains and left ventricular ejection fraction compared with normal cases. There was strong agreement between cine DENSE and MTT on the basis of intraclass correlation coefficients (CURE: 0.99, 95% CI: 0.96 to 1.00; LURE: 0.92, 95% CI: 0.77 to 0.98; circumferential strain [ECC]: 0.95, 95% CI: 0.72 to 0.99; longitudinal strain [ELL]: 0.82, 95% CI: 0.42 to 0.97). The FT-based metrics (scale 0 to 1), in particular CURE, discriminated highly between LBBB-HF and NQRS-HF groups (median difference): CURE: 0.60, 95% CI: 0.43 to 0.76; LURE: 0.39, 95% CI: 0.19 to 0.58; radial uniformity ratio estimate: 0.22, 95% CI: 0.04 to 0.40). In contrast, relative confidence intervals for group differences in time-to-peak parameters were wide, indicating less consistent discrimination (median difference): SD12-ECC: 52.5, 95% CI: −4.0 to 109.2; SD12-ELL: 40.9, 95% CI: −5.3 to 87.1; SD12-radial strain: 42.0, 95% CI: 0.4 to 83.6). Correlations between FT-based and time-to-peak parameters were significant (CURE/SD12-ECC: r = −0.62, p = 0.03; LURE/SD12-ELL: r = −0.76, p = 0.005) but not as tight as correlations between time-to-peak parameters.ConclusionsAutomated FT-based circumferential, radial, and longitudinal dyssynchrony measures compare favorably with time-to-peak parameters. Cine DENSE was effective for this application and validated with MTT. Further clinical evaluation in cardiac resynchronization therapy candidates with CMR or other imaging modalities is warranted.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Imaging - Volume 5, Issue 8, August 2012, Pages 789–797
نویسندگان
, , , , , ,