کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2938478 1176941 2010 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An Alternative Isovelocity Surface Model for Quantitation of Effective Regurgitant Orifice Area in Mitral Regurgitation With an Elongated Orifice : Application to Functional Mitral Regurgitation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
An Alternative Isovelocity Surface Model for Quantitation of Effective Regurgitant Orifice Area in Mitral Regurgitation With an Elongated Orifice : Application to Functional Mitral Regurgitation
چکیده انگلیسی

ObjectivesThe purpose of this study was to develop and test a simple, clinically practical alternative isovelocity surface (ISVS) model for calculating effective regurgitant orifice area (EROA) in mitral regurgitation (MR) when the regurgitant orifice is elongated, such as in functional MR.BackgroundClinical experience and 3-dimensional imaging suggest that the traditional hemispheric ISVS model used in the conventional proximal isovelocity surface area (PISA) calculation is invalid in certain MR cases and can cause erroneous EROA values.MethodsOur ISVS model consisted of 3 sections of equal radius (R): a cylindrical midsection of length (L) positioned between 2 hemispheroidal end sections. Total ISVS area (TS) is equal to 2πR2 + πLR and EROA is equal to (VN/VCW)TS, where VN is the flow velocity crossing perpendicular to the ISVS, and VCW is the peak MR jet velocity by continuous-wave Doppler. This EROA was corrected for any obtuse angle, θ formed by tented leaflets, by multiplying TS by a planar factor, (θ/180) or a combination of this planar factor for the cylindrical midsection and the solid-angle factor, 1−cos(θ/2), for the 2 spheroidal end sections. In 24 cases of severe or 3+ functional MR, we calculated EROA using 3 traditional hemispheric surfaces and 3 alternative ISVS models that differed in the leaflet angle correction applied. Results were compared with continuity-based EROA using the standard mitral valve − aortic valve stroke volume method and with predictions based upon theoretical geometric considerations.ResultsThe mean differences between continuity EROA and ISVS area–based EROA for no angle correction, planar correction, or combined angle correction were, respectively, 0.38, 0.32, and 0.28 cm2 for the 3 spherical surface models and 0.17, 0.018, and −0.012 cm2 for the 3 alternative 3-section ISVS models. The empiric EROA results with both the traditional spherical and alternative ISVS models agreed well with theoretical geometric predictions.ConclusionsThe traditional spherical PISA model underestimates EROA in functional MR. For elongated MR orifices, an ISVS model that mirrors orifice shape yields more accurate EROA values. Correction to the ISVS area for obtuse leaflet angulation improves accuracy of EROA estimation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Imaging - Volume 3, Issue 11, November 2010, Pages 1091–1103
نویسندگان
, ,