کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2939139 1176974 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Diagnostic Accuracy of Coronary Computed Tomography Angiography as Interpreted on a Mobile Handheld Phone Device
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Diagnostic Accuracy of Coronary Computed Tomography Angiography as Interpreted on a Mobile Handheld Phone Device
چکیده انگلیسی

ObjectivesThis study assessed the diagnostic performance of coronary computed tomography angiography (CTA) for the detection and exclusion of significant coronary artery stenosis as remotely interpreted on a mobile handheld device with dedicated medical imaging software.BackgroundRecent advances in technology now permit remote interpretation of medical imaging studies on mobile handheld devices, although the diagnostic performance of this approach is unknown.MethodsWe evaluated 102 patients with stable chest pain and both 64-detector row coronary CTA and quantitative invasive coronary angiography. The diagnostic performance of remote coronary CTA interpretation was assessed using a mobile handheld device and employing dedicated software. The coronary CTA studies were examined in an intent-to-diagnose manner for the presence or absence of coronary artery stenosis ≥50% on a per-artery and per-patient level; results were compared with quantitative invasive coronary angiography. Two blinded imagers independently interpreted coronary CTA studies, with a third imager achieving consensus for discordance. Coronary CTAs were re-interpreted in random order to determine interobserver agreement. Finally, coronary CTAs were evaluated on a dedicated 3-dimensional imaging workstation; results were compared to mobile handheld device findings for intertechnology agreement.ResultsThe prevalence of significant coronary artery stenosis was 25% (26 of 102) at the per-patient level and 10% (40 of 405) at the per-artery level. Per-patient and per-artery sensitivity, specificity, and positive and negative predictive values were: 100% (26 of 26), 78% (59 of 76), 60% (26 of 43), and 100% (59 of 59), respectively; and 95% (38 of 40), 85% (310 of 365), 41% (38 of 93), and 99% (310 of 312), respectively. At the per-artery level, interobserver, intraobserver, and intertechnology agreement was 0.74, 0.89, and 0.75, respectively (p < 0.01 for all).ConclusionsThe interpretation of coronary CTA using a mobile handheld device with dedicated software for medical image evaluation possesses high diagnostic accuracy for detection and exclusion of significant coronary stenosis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Imaging - Volume 3, Issue 5, May 2010, Pages 482–490
نویسندگان
, , , , , ,