کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2964076 1178635 2010 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Resolution of thrombus in left ventricular outflow tract pseudoaneurysm mimicking periaortic abscess
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Resolution of thrombus in left ventricular outflow tract pseudoaneurysm mimicking periaortic abscess
چکیده انگلیسی

SummaryProsthetic valve complications are not uncommon after valve replacement. In this paper we report a female patient who presented with aortic prosthetic valve endocarditis and echocardiographic appearance of periaortic abscess. After 6 weeks of antibiotic therapy, echocardiographic examination revealed resolution of abscess cavity and replacement with a clear blood-filled anechoic sac. Diagnosis was made by cardiac computed tomography, which showed a left ventricular outflow tract (LVOT) pseudoaneurysm rather than an abscess, located just below the sewing ring of the prosthetic aortic valve. We assumed that either resolution of thrombus in LVOT pseudoaneurysm following effective warfarin therapy or clearance of infective content in pseudoaneurysm after co-administered antibiotics gave rise to change in echocardiographic characteristics in the perivalvular area.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cardiology Cases - Volume 2, Issue 3, December 2010, Pages e128–e131
نویسندگان
, , , , , , , ,