کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3097468 | 1190944 | 2011 | 4 صفحه PDF | دانلود رایگان |

BackgroundComplex intracranial aneurysms are often treated with endovascular stent-assisted coiling. Intracranial stents are difficult to visualize with conventional computed tomography (CT) or fluoroscopy. “Stent view” flat-detector CT can be used to visualize intracranial stents during endovascular treatment.MethodsThree patients underwent endovascular treatment of complex intracranial aneurysms. Stent view flat-detector CT was used to study stent placement and morphology in vivo.ResultsStent view CT was successful in visualizing stents in all patients. In two patients, stent morphology rendered endovascular coiling technically unfeasible; in one patient, visualization of stent strut herniation into the aneurysm lumen allowed successful coil embolization of the aneurysm.ConclusionsStent view CT provided detailed imaging of stent placement and morphology in all three cases. The technique influenced treatment decisions and technical outcomes. Stent view CT is a valuable intraprocedural technical tool in stent-assisted endovascular procedures.
Journal: World Neurosurgery - Volume 75, Issue 2, February 2011, Pages 275–278