کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
312381 | 534211 | 2014 | 7 صفحه PDF | دانلود رایگان |
• Early age bond strength of shotcrete on granite rock is studied.
• A newly developed test set-up for early age bond strength is presented.
• Different bond failure modes are characterized.
This study investigates early age bond strength of shotcrete (sprayed concrete), in the case of shotcrete sprayed on hard rock. Shotcrete differs from ordinary, cast concrete through the application technique and the addition of set accelerators which give immediate stiffening. The bond between shotcrete and rock is one of the most important properties. During the very first time after spraying the physical properties and the bond to the rock depend on the set accelerator and the micro structure that is formed. In this work a laboratory test method for measuring early bond strength for very young or early age shotcrete is presented. The newly developed method was tested and evaluated and proved that it can be used for bond strength testing already from a couple of hours after shotcreting.
Figure optionsDownload as PowerPoint slide
Journal: Tunnelling and Underground Space Technology - Volume 41, March 2014, Pages 113–119