کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3146022 1197136 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Pre-heating of high-viscosity bulk-fill resin composites: Effects on shrinkage force and monomer conversion
ترجمه فارسی عنوان
پیش گرم کردن کامپوزیت های رزین با فشرده سازی باکیفیت بالا: تاثیر بر نیروی انقباض و تبدیل مونومر
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
چکیده انگلیسی

ObjectivesTo investigate the influence of pre-heating of high-viscosity bulk-fill composite materials on their degree of conversion and shrinkage force formation.MethodsFour bulk-fill composite materials (Tetric EvoCeram Bulk Fill—TECBF, x-tra fil—XF, QuixFil—QF, SonicFill—SF) and one conventional nano-hybrid resin composite (Tetric EvoCeram—TEC) were used. The test materials were either kept at room temperature or pre-heated to 68 °C by means of a commercial heating device, before being photoactivated with a LED curing unit for 20 s at 1170 mW/cm2. Shrinkage forces (n = 5) of 1.5-mm-thick specimens were recorded in real-time for 15 min inside a temperature-controlled chamber at 25 °C (simulating intraoral temperature after rubber dam application) with a custom-made stress analyzer. Degree of conversion (n = 5) was determined at the bottom of equally thick (1.5 mm) specimens using Fourier transform infrared spectroscopy. Data were analyzed with Student’s t-test, ANOVA and Tukey’s HSD post-hoc test (α = 0.05).ResultsComposite pre-heating significantly increased the degree of conversion of TECBF, but had no effect on monomer conversion of the other materials investigated. For each of the test materials, pre-heated composite generated significantly lower shrinkage forces than room-temperature composite. At both temperature levels, TECBF created the significantly highest shrinkage forces, and QF caused significantly higher shrinkage forces than both XF and TEC.ConclusionsBoth the composite material and the pre-cure temperature affect shrinkage force formation. Pre-heating of bulk-fill and conventional restorative composites prior to photoactivation decreases polymerization-induced shrinkage forces without compromising the degree of conversion.Clinical significanceComposite pre-heating significantly reduces shrinkage force formation of high-viscosity bulk-fill and conventional resin composites, while maintaining or increasing the degree of monomer conversion, dependent upon the specific composite material used.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Dentistry - Volume 43, Issue 11, November 2015, Pages 1358–1364
نویسندگان
, , , ,