کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3146290 1197205 2012 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effects of sports drinks on color stability of nanofilled and microhybrid composites after long-term immersion
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Effects of sports drinks on color stability of nanofilled and microhybrid composites after long-term immersion
چکیده انگلیسی

ObjectivesThis study assessed the effects of three sports drinks on the color stability of two nanofilled and two microhybrid composite materials after 1-month and 6-month periods.Materials and methodsTwenty-eight disc-shaped specimens (diameter: 10 mm and thickness: 2 mm) each were made from four resin composites (Clearfil Majesty Posterior, Filtek Supreme, Clearfil APX, and Filtek Z250). All the specimens were stored in distilled water for 24 h at 37 °C. Then, the baseline color values (L*a*b*) of each specimen were measured using a spectrophotometer according to the CIEL*a*b* color scale. Seven randomly selected specimens from each composite material were then immersed in one of the three sports drinks (Powerade, Red Bull, and Burn) or distilled water (control) for 1 and 6 months. After each immersion, the color values of each specimen were remeasured, and the color change value (ΔE) was calculated. The data were evaluated using the Kruskal–Wallis and Mann–Whitney U-tests.ResultsThe tested resin composites showed color changes over the 6-month evaluation periods. At 1 month, highest level of color changes was observed in the Clearfil APX specimens immersed in Burn (p < 0.01). Clearfil Majesty Posterior showed less discoloration in all the composite materials tested after 6 months (p < 0.001). Independent of the composite materials tested, Burn resulted in the highest level of discoloration after both immersion periods (p < 0.01).ConclusionAll the test solutions used in the present study caused greater discoloration than the clinically acceptable level of threshold (ΔE < 3.3) over the 6-month evaluation period except for Clearfil Majesty Posterior immersed in distilled water (2.91 ± 0.28). The effect of each solution on the color stability of the composite materials depended on the type of solution, exposure time, and composition of the composite material.Clinical significanceThe effect of a solution on color stability of composite materials depends on the type of solution, exposure time, and composition of the material. In clinical practice, patients should be aware of the staining effects and erosive potential of sports drinks if consumed a longer period of time.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Dentistry - Volume 40, Supplement 2, December 2012, Pages e55–e63
نویسندگان
, , ,