Assessment of the Stratos, a New Pencil-Beam Bone Densitometer: Dosimetry, Precision, and Cross Calibration
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
غدد درون ریز، دیابت و متابولیسم
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Assessment of the Stratos, a New Pencil-Beam Bone Densitometer: Dosimetry, Precision, and Cross Calibration Assessment of the Stratos, a New Pencil-Beam Bone Densitometer: Dosimetry, Precision, and Cross Calibration](/preview/png/3271262.png)
چکیده انگلیسی
The goal of this study was to assess a new pencil-beam densitometer, the Stratos (Diagnostic Medical Systems, Pérols, France). Evaluation of the dosimetry and precision were done together with an in vivo cross-calibration study performed with the fan beam densitometer Discovery A (Hologic, Bedford, MA). The results indicated that the Stratos performed bone mineral density (BMD) measurements with a good precision, low radiation dose, and good agreement with the Discovery A. The air dose, measured by an ionization chamber, was 40 μGy. The effective dose was assessed using an anthropomorphic phantom and thermoluminescent detectors resulting in 1.96 and 0.31 μSv for a lumbar spine and proximal femur scan, respectively. The average scattered dose rate at a distance of 1 m from the device was 1.06 and 1.21 μSv.hâ1 in the lumbar spine and left proximal femur scan mode, respectively. For the precision evaluation, 30 patients underwent 2 lumbar spine and 2 proximal femur scans with repositioning after each scan. The percentage root-mean-square coefficient of variation was 1.22%, 1.38%, 2.11%, and 0.86% for the lumbar spine (L1-L4), lumbar spine (L2-L4), femoral neck, and total hip, respectively. The cross-calibration studies were done on 57 patients (60 ± 9 yr). Lumbar spine, left neck, and left total hip mean BMD were 3.10% lower and 11.94% and 8.83% higher, respectively, with the Stratos compared with the Discovery A. Cross-calibration equations were calculated with a correlation coefficient of 98% (p < 0.01) for the lumbar spine (L2-L4), 94% (p < 0.01) for the left neck, and 92% (p < 0.01) for the left total hip. After standardizing the Stratos measures using the cross-calibration equations, LIN's concordance correlation coefficient was 0.98, 0.93, and 0.92 for the lumbar spine (L2-L4), left neck, and total hip, respectively.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Clinical Densitometry - Volume 14, Issue 4, OctoberâDecember 2011, Pages 395-406
Journal: Journal of Clinical Densitometry - Volume 14, Issue 4, OctoberâDecember 2011, Pages 395-406
نویسندگان
Enrique Nalda, Krishna Kunal Mahadea, Christophe Dematteï, Pierre-Olivier Kotzki, Jean-Pierre Pouget, Vincent Boudousq,