کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3417509 1593765 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Direct blood culturing on solid medium outperforms an automated continuously monitored broth-based blood culture system in terms of time to identification and susceptibility testing
ترجمه فارسی عنوان
کشت مستقیم بر روی محیط جامد از یک سیستم کنترل فرهنگی مبتنی بر متابولیت به صورت پیوسته نظارت خودکار به لحاظ زمان برای شناسایی و آزمایش حساسیت
کلمات کلیدی
آزمایش حساسیت ضد میکروبی، باکترمیوم عفونت های خون تشخیص، کشت مستقیم مستقیم شناسایی، تشخیص سریع سپسیس، محیط جامد
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروب شناسی
چکیده انگلیسی

Pathogen identification and antimicrobial susceptibility testing (AST) should be available as soon as possible for patients with bloodstream infections. We investigated whether a lysis-centrifugation (LC) blood culture (BC) method, combined with matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) identification and Vitek 2 AST, provides a time advantage in comparison with the currently used automated broth-based BC system. Seven bacterial reference strains were added each to 10 mL human blood in final concentrations of 100, 10 and 1 CFU/mL. Inoculated blood was added to the Isolator 10 tube and centrifuged at 3000 g for 30 min, then 1.5 mL sediment was distributed onto five 150-mm agar plates. Growth was observed hourly and microcolonies were subjected to MALDI-TOF MS and Vitek 2 as soon as possible. For comparison, seeded blood was introduced into an aerobic BC bottle and incubated in the BACTEC 9240 automated BC system. For all species/concentration combinations except one, successful identification and Vitek 2 inoculation were achieved even before growth detection by BACTEC. The fastest identification and inoculation for AST were achieved with Escherichia coli in concentrations of 100 CFU/mL and 10 CFU/mL (after 7 h each, while BACTEC flagged respective samples positive after 9.5 h and 10 h). Use of the LC-BC method allows skipping of incubation in automated BC systems and, used in combination with rapid diagnostics from microcolonies, provides a considerable advantage in time to result. This suggests that the usefulness of direct BC on solid medium should be re-evaluated in the era of rapid microbiology.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: New Microbes and New Infections - Volume 10, March 2016, Pages 19–24
نویسندگان
, , , ,