کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3981777 1257704 2014 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum
ترجمه فارسی عنوان
آرتروگرافی توموگرافی کامپیوتری با کشش در هوای انسانی برای بازسازی سه بعدی غضروف و آزمایشگاه استابولار
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی تومور شناسی
چکیده انگلیسی


• We present a hip CTA protocol to clearly delineate the intra-articular space.
• A Hare traction splint provides a simple, cost-effective way to apply traction.
• The required traction force depends on individual hip morphology.
• The traction force can be adjusted using the Hare traction splint.

AimTo develop and demonstrate the efficacy of a computed tomography arthrography (CTA) protocol for the hip that enables accurate three-dimensional reconstructions of cartilage and excellent visualization of the acetabular labrum.Materials and methodsNinety-three subjects were imaged (104 scans); 68 subjects with abnormal anatomy, 11 patients after periacetabular osteotomy surgery, and 25 subjects with normal anatomy. Fifteen to 25 ml of contrast agent diluted with lidocaine was injected using a lateral oblique approach. A Hare traction splint applied traction during CT. The association between traction force and intra-articular joint space was assessed qualitatively under fluoroscopy. Cartilage geometry was reconstructed from the CTA images for 30 subjects; the maximum joint space under traction was measured.ResultsUsing the Hare traction splint, the intra-articular space and boundaries of cartilage could be clearly delineated throughout the joint; the acetabular labrum was also visible. Dysplastic hips required less traction (∼5 kg) than normal and retroverted hips required (>10 kg) to separate the cartilage. An increase in traction force produced a corresponding widening of the intra-articular joint space. Under traction, the maximum width of the intra-articular joint space during CT ranged from 0.98–6.7 mm (2.46 ± 1.16 mm).ConclusionsWhen applied to subjects with normal and abnormal hip anatomy, the CTA protocol presented yields clear delineation of the cartilage and the acetabular labrum. Use of a Hare traction splint provides a simple, cost-effective method to widen the intra-articular joint space during CT, and provides flexibility to vary the traction as required.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Radiology - Volume 69, Issue 10, October 2014, Pages e381–e391
نویسندگان
, , , , , ,