کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3983335 1257761 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Three-dimensional gadolinium-enhanced MR venography to evaluate central venous steno-occlusive disease in hemodialysis patients
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی تومور شناسی
پیش نمایش صفحه اول مقاله
Three-dimensional gadolinium-enhanced MR venography to evaluate central venous steno-occlusive disease in hemodialysis patients
چکیده انگلیسی

AimTo determine the agreement and diagnostic accuracy of three-dimensional gadolinium-enhanced magnetic resonance venography (3D-Gd-MRV) in central venous steno-occlusive disease (CVSD) in haemodialysis patients.Materials and methodsFourteen consecutive haemodialysis patients underwent interventional procedures to evaluate or treat CVSD. 3D-Gd-MRV was performed before the procedures and the results were compared with digital subtraction angiography (DSA).ResultsDSA showed >50% stenosis in all 14 patients, 13 of whom were diagnosed correctly using 3D-Gd-MRV. Moderate stenosis was missed at 3D-Gd-MRV in one case whereby the indwelling dialysis central venous catheter may have caused an artefact on the images and hindered the accuracy of the result. The sensitivity of 3D-Gd-MRV in revealing stenosis was 93% (13/14). No complications caused by contrast agent toxicity occurred in any patient.Conclusion3D-Gd-MRV employing a non-breath-hold technique is highly sensitive in the diagnosis of CVSD and may be an alternative technique to DSA for the visualization of central veins.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Radiology - Volume 67, Issue 6, June 2012, Pages 560–563
نویسندگان
, , , , , ,