کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4000503 1259378 2011 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Acute toxicity of image-guided hypofractionated radiotherapy for prostate cancer: Nonrandomized comparison with conventional fractionation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی تومور شناسی
پیش نمایش صفحه اول مقاله
Acute toxicity of image-guided hypofractionated radiotherapy for prostate cancer: Nonrandomized comparison with conventional fractionation
چکیده انگلیسی

ObjectivesTo compare acute toxicity of prostate cancer image-guided hypofractionated radiotherapy (hypo-IGRT) with conventional fractionation without image-guidance (non-IGRT). To test the hypothesis that the potentially injurious effect of hypofractionation can be counterbalanced by the reduced irradiated normal tissue volume using IGRT approach.Materials and methodsOne hundred seventy-nine cT1-T2N0M0 prostate cancer patients were treated within the prospective study with 70.2 Gy/26 fractions (equivalent to 84 Gy/42 fractions, α/β 1.5 Gy) using IGRT (transabdominal ultrasound, ExacTrac X-Ray system, or cone-beam computer tomography). Their prospectively collected data were compared with data of 174 patients treated to 80 Gy/40 fractions with non-IGRT. The difference between hypo-IGRT and non-IGRT cohorts included fractionation (hypofractionation vs. conventional fractionation), margins (hypo-IGRT margins: 7 mm and 3 mm, for all but posterior margins; respectively; non-IGRT margins: 10 and 5 mm, for all but posterior margins, respectively), and use of image-guidance or not. Multivariate analysis was performed to define the tumor-, patient-, and treatment-related predictors for acute toxicity.ResultsAll patients completed the prescribed radiotherapy course. Acute toxicity in the hypo-IGRT cohort included rectal (G1: 29.1%; G2: 11.2%; G3: 1.1%) and urinary events (G1: 33.5%; G2: 39.1%; G3: 5%). Acute toxicity in the non-IGRT patients included rectal (G1: 16.1%; G2: 6.3%) and urinary events (G1: 36.2%; G2: 20.7%; G3: 0.6%). In 1 hypo-IGRT and 2 non-IGRT patients, radiotherapy was temporarily interrupted due to acute toxicity. The incidence of mild (G1-2) rectal and bladder complications was significantly higher for hypo-IGRT (P = 0.0014 and P < 0.0001, respectively). Multivariate analysis showed that hypo-IGRT (P = 0.001) and higher PSA (P = 0.046) are correlated with higher acute urinary toxicity. No independent factor was identified for acute rectal toxicity. No significant impact of IGRT system on acute toxicity was observed.ConclusionsThe acute toxicity rates were low and similar in both study groups with some increase in mild acute urinary injury in the hypo-IGRT patients (most probably due to the under-reporting in the retrospectively analyzed non-IGRT cohort). The higher incidence of acute bowel reactions observed in hypo-IGRT group was not significant in the multivariate analysis. Further investigation is warranted in order to exclude the bias due to the nonrandomized character of the study.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Urologic Oncology: Seminars and Original Investigations - Volume 29, Issue 5, September–October 2011, Pages 523–532
نویسندگان
, , , , , , , , , , , , , ,